Broadway Collection Towel Warmers Installation, Operation & Maintenance Instructions
_______________________________________________________________
3
Install Towel Warmers in upright position only. Locate wir-
ing box with indicator light on bottom as shown. Failure to
install properly may result in overheating and a hazardous
condition.
IMPORTANT NOTE:
Towel Warmers may have small
dimensional variations and must be measured prior to
installation. Do not use dimensions to determine location
of mounting holes.
C
D
B
A
Locate wiring
box as shown
MOUNTING DIMENSIONS (inches)
MODEL A B C D
W216C 4
5
⁄16 1
3
⁄8 11 13
3
⁄8
W219C 4
5
⁄16 1
3
⁄8 15 13
3
⁄4
W228C 4
5
⁄16 1
3
⁄8 15 21
5
⁄8
W236C 4
5
⁄16 1
3
⁄8 15 29
1
⁄2
W248C 4
5
⁄16 1
3
⁄8 15 41
3
⁄8
!
WARNING
This
End
Up
Upper Header (Z)
Lower Header (Z)
Wiring
Box
Finished
wall surface
Towel Warmer
Y
X
MOUNTING DIMENSIONS (inches)
MODEL X
(min)
Y Z
(min)
(Header horizontal length) (Header vertical length) (Header size)
W216C 12 13
3
⁄8 2 x 6
W219C 16 13
3
⁄4 2 x 6
W228C 16 21
5
⁄8 2 x 6
W236C 16 29
1
⁄2 2 x 6
W248C 16 41
3
⁄8 2 x 6
For Technical Service Assistance:
East Coast Tel: 1-800-767-8326
West Coast Tel: 1-800-727-8326
WALL PREPARATION
• DO NOT mount the Towel Warmer without provid-
ing structurally secure upper and lower headers as
shown.
• DO NOT mount the Towel Warmer directly to
sheet rock or any other non-structural surface.
• Use longer fasteners as required if the finished
wall surface prevents adequate mounting with the
screws provided.
• Provide a clearance hole in the lower header as
required to route field wiring to the Towel Warmer
wiring box.
IMPORTANT NOTE:
See electrical rough-in
instructions on page 6.
IMPORTANT NOTE:
Towel Warmers may have
small dimensional variations and must be measured
prior to installation. Do not use dimensions to deter-
mine location of mounting holes.
!
CAUTION