mr
.
steam
®
Feel Good Inc.
Installation, Operation and Maintenance Manual
Steambath Generator Systems
Residential
Models: MS90E MS400E and MSSUPER1E 6E
Vista de pagina 0
1 2 3 4 5 6 ... 45 46

Indice de contenidos

Pagina 1

mr.steam®Feel Good Inc.™Installation, Operation and Maintenance ManualSteambath Generator SystemsResidentialModels: MS90E – MS400E and MSSUPER1E – 6E

Pagina 2 - SAVE THESE INSTRUCTIONS

8K12””for servicingLIJHGFABCDEMGENERATOR DIAGRAMMS 90E- MS 400E MS Super 1E-3E_______________________________________A5 (127) 71⁄4 (184)B81⁄8 (206) 97

Pagina 3

TransformerLiquid LevelControl BoardWater FeedSolenoidWater FeedLiquidLevel ProbeAutoFlush®Plug andPlay Connection(see page 14)FusesContactorPower Blo

Pagina 4 - Mr.Steam @ Your Fingertips:

FACTO RYWIRIN GFIELDWIRIN GLE G E N D(All Diagrams)CONTACTORHEATING ELEMENTTO PROBECONTROL BOARDAutoFlushSteamGenie oriGenie(optional)iSteam, iTempoor

Pagina 5

INSTALLATION INSTRUCTIONSFOR MODELS: MS-SUPER 4E, MS-SUPER 5E AND MS-SUPER 6E1.Install each unit as in a single installation. Install the two generato

Pagina 6

INITIAL START-UP AND CHECKOUT1. Turn on control. Follow specific instructions provided with controls.2. Steam will begin to appear in approximately 5

Pagina 7

mr.steam®Installation, Operation & Maintenance Manual__________________________________________________________________________I N S T A L L E R13

Pagina 8

I N S T A L L E R14OPTIONAL AUTOFLUSH®Box ContentsAutoFlush Valve with CordInstallation Instructions.OPERATIONThe optional AutoFlush System feature au

Pagina 9

I N S T A L L E R15OPTIONAL DRIP PANMr. Steam strongly recommends the use of a drippan in the unlikely event of a plumbing leak.Locate the drip pan on

Pagina 10 - I N S T A L L E R

TransformerLiquid LevelControl BoardWater FeedSolenoidWater InletSafety ValveAutoFlushValve(optional)Stainless Steel TankHeating ElementExpress Steamh

Pagina 11

REPLACEMENT PARTS LIST__________________________________________________________________________________________Part No. Description Generator________

Pagina 12

mr.steam®Sussman-Automatic Corporation®[email protected] www.mrsteam.com43-20 34th Street, Long Island City, NY 11101 TEL: 1 800 76 STEAM FAX: 718 472

Pagina 13

CONTROL ROUGH INRefer to Installation Instructions for the specific controlIMPORTANT NOTE: The control cable should be run in adedicated 1” conduit to

Pagina 14

READ ME FIRST!As you follow theseinstructions, you will notice warningand caution symbols. This blockedinformation is important for the safeand effici

Pagina 15

CARE TIPS FOR ALL CONTROLS ANDSTEAMHEADS1. Use only mild soap and water on a soft cloth to cleanthe control and steamhead.2. DO NOT use abrasive clean

Pagina 16

21mr.steam®Installation, Operation & Maintenance Manual__________________________________________________________________________H O M E O W N E R

Pagina 17

mr.steam®Feel Good Inc.™www.mrsteam.commr.steam®Sussman-Automatic Corporation®[email protected] 34th Street, Long Island City, N

Pagina 18

iTEMPO™ & iTEMPOPLUS™ CONTROLSInstallation, Operation & Maintenance Manual mr.steam® Feel Good Inc.www.mrsteam.com

Pagina 19

HYPERTHERMIA occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6° F. The sympto

Pagina 20

mr.steam® Installation & Operating Instructions______________________________________________________________3READ ME FIRST! As you follow thes

Pagina 21 - INSTRUCTIONS

mr.steam® Installation & Operating Instructions______________________________________________________________4BEFORE INSTALLINGCarefully inspect

Pagina 22 - H O M E O W N E R

mr.steam® Installation & Operating Instructions______________________________________________________________521/2”41/2”1/4”3/8”3/4”1”5”5”33/4”1

Pagina 23

RESIDENTIAL STEAMBATH GENERATOR SYSTEMSINSTALLATION, OPERATION & MAINTENANCE MANUALMODELS: MS-90E, MS-150E, MS-225E, MS-400E, MS-SUPER 1E,MS-SUPER

Pagina 24 - Feel Good Inc

mr.steam® Installation & Operating Instructions______________________________________________________________6DIAGRAM 2Installation Instructions

Pagina 25

mr.steam® Installation & Operating Instructions______________________________________________________________7NOTE: The connector is keyed with

Pagina 26

mr.steam® Installation & Operating Instructions______________________________________________________________8DIAGRAM 6Drawings for Illustrative

Pagina 27 - Table of Contents:

mr.steam® Installation & Operating Instructions______________________________________________________________9Drawings for Illustrative Purposes

Pagina 28

mr.steam® Installation & Operating Instructions______________________________________________________________10Mr.Steam Steam Generator(shown wi

Pagina 29 - and iTempoPlus

mr.steam® Installation & Operating Instructions______________________________________________________________115. Route the end of the probe cab

Pagina 30 - DIAGRAM 2

mr.steam® Installation & Operating Instructions______________________________________________________________12The iTempo Control features progr

Pagina 31 - DIAGRAM 4

mr.steam® Installation & Operating Instructions______________________________________________________________13DisplayUp KeyPause KeyDown KeyON/

Pagina 32 - DIAGRAM 5

mr.steam® Installation & Operating Instructions______________________________________________________________14mr.steamtemparoma chromatimemr

Pagina 33

mr.steam® Installation & Operating Instructions______________________________________________________________15Drawings for Illustrative Purpose

Pagina 34 - Mr.Steam Steam Generator

2Materials of construction, room size and special design features suchas large glass areas, all affectthe steam generator model selection.1.Measure le

Pagina 35 - r o o m i n t e r i o r

mr.steam® Installation & Operating Instructions______________________________________________________________16mr.steamaroma chromatimemr.ste

Pagina 36

mr.steam® Installation & Operating Instructions______________________________________________________________17mr.steamchromatimetemparomamr.ste

Pagina 37

mr.steam® Installation & Operating Instructions______________________________________________________________18Care Tips for all Controls and St

Pagina 38 - Operating Instructions

mr.steam® Installation & Operating Instructions______________________________________________________________19 te mpl ate for contro l i nstal

Pagina 39

Products, information and specifications are subject to change without notice. For more information call Sales & Support at:1.800.76.STEAM (East Co

Pagina 40 - DIAGRAM 8

AutoFlush CordAutoFlush Valve3 Pin Connector for AutoFlushAutoFlushCordConnectorDrain Valve(shown in the correct open position)DO NOT REMOVE THIS DRAI

Pagina 41 - DIAGRAM 10

INSTALLING AUTOFLUSH ON OLDER MODELGENERATORS SN:899,999 and below1. Remove the connector from the "C" location inthe jacket. Cut off the co

Pagina 42 - Warranty

I N S T A L L E R3If acrylic, fiberglass or other non-heat resistant mate-rials are used as part of the steam room enclosure. Consult with thematerial

Pagina 43 - (se e p g.6)

LOCATING THE STEAM GENERATORSelect a location as near as practical to the steam room.Typical locations include: closet, vanity cabinet, heated attic o

Pagina 44

TYPICAL INSTALLATION INSTRUCTIONSFOR MODELS MS SUPER 4E, 5E & 6E(shown with optional AutoFlush)1. Install each steam generator as in a single inst

Pagina 45 - PUR 100200 Rev 5.13

INSTALLATIONPLUMBINGAll plumbing shall be performed by a qualified licensed plumber andin accordance with applicable National and local codes.1. Use u

Pagina 46 - WARRANTY:

SteamSupply PipeEnd of pipe to be recessed1/4"(without Acrylic Shield)1/8" (with Acrylic Shield)1/8" minimum clearance requiredwhen Acr